General features |
Capacity |
2,685 Wh |
|
Nominal voltage |
25.9 V |
|
Final charging voltage |
29.05 V |
|
Final discharging voltage |
21.0 V |
|
Nominal charge |
104 Ah |
|
Maximum discharge rate |
180 A |
Safety function against short-circuit, must not be used as starter battery |
Maximum discharge rate at nominal voltage |
4,500 W |
|
Weight |
24.3 kg |
|
Dimensions (L x H x B) |
577.5 mm x 218.5 mm x 253.5 mm |
|
Volume |
32 l |
|
Battery chemistry |
Li NMC |
|
|
Benchmark information |
Energy density (weight) |
110 Wh/kg |
|
Energy density (volume) |
84 Wh/l |
|
Price-performance |
EUR 0.93 /Wh |
|
Power density (weight) |
185 W/kg |
|
Power density (volume) |
141 W/l |
|
|
Lifetime data |
Cycle lifetime |
800 cycles with 100%
discharge depth at 25°C |
result in capacity loss of approx. 25% |
Average annual capacity loss |
Approx. 4% at 25°C ambient temperature |
|
|
Usage information |
Cell operating temperature |
-20°C to +60°C |
Battery protects itself |
Cell charging temperature |
0°C to +55°C |
Battery protects itself |
Temperature (storage) |
-30°C to +55°C |
|
Typical storage time at 50% SOC |
1 year |
When switched off |
Max. connections |
2S8P or 1S16P |
Please contact Torqeedo if larger battery banks required |
Max. quick charge |
100 A |
Charging time < 1.2 hours |
Protection class |
IP67 |
Waterproof, can be submerged to depth of 1 metre for 30 minutes without damage |
|
Battery composition |
Number of cells |
336 |
|
Cell housing |
Steel cylinder safety cells |
|
Capacity per cell |
2.25 Ah |
|
Nominal voltage per cell |
3.7 V |
|
Cell connection |
7s48p |
|
|
Battery management system and safety |
On-off switch |
Yes |
Via Cruise or motors or on/off switch |
Cell balancing |
Yes |
Increases the battery lifetime |
High-current and short-circuit protection |
Yes |
4-level safety cut-out mechanism to protect against short-circuits and overcurrent |
Deep discharge protection |
Yes, cut-off at < 2.7 V per cell,
charge protection at < 2 V per cell |
|
Protection against incorrect charging |
Yes |
3 protection levels against overcharging |
Protection against polarity reversal |
Yes |
|
Individual cell voltage monitoring |
Yes |
|
Current interruption device (CID) for each cell |
Yes |
|
Safety vent for each cell |
Yes |
|
Cell temperature monitoring |
Yes |
|
Temperature monitoring of battery electronics |
Yes |
|
Automatic shutdown in the event of submersion |
Yes |
|
|
Information system |
Interface |
RS485 |
|
Electronic battery identification |
Yes |
Important for connecting multiple batteries into battery banks |
Data logging |
Yes |
Important for warranty information |